DeltaVision® Imaging Systems Technical Specifications

DeltaVision Core Specs / personalDV Specs


DeltaVision Core

( Specifications subject to change )
    System Configuration
  • LED transillumination
  • APLLC Xe illumination
  • Fast shutter
  • 10-position ND filter wheel
  • 10-position EX filter wheel
  • 6-position EM filter wheel
  • Optical fiber
  • Fiber Optical Module (FOM)
  • IX-71 microscope base
  • Custom DeltaVision Quad filter set
  • 60x objective/1.42NA
  • 50 mm long travel stage
  • CoolSnap HQ2 Camera
  • DeltaVision microscopy platform
  • DeltaVision electronics rack
  • Dual processor, dual core computer 1TB RAID5
  • 24" monitor
  • Backlit keyboard, laser mouse
  • Data Management Solution (DMS)
    Instrument Control
  • Instrument Control (IC) computer
  • Microscope Interface Chassis (MIC)
  • Lamp power supplies
  • NanoMotion® III position control
  • Single rackmounted IC/MIC enclosure design
  • Faster performance
    Stage Specifications
    Z axis
  • Absolute accuracy
    - < 0.6 um per 13 um Z scan
    - < 2.0 um per 100 um Z scan
  • Out-of-axis motion
    - < 0.6 um per 13 um Z scan (< 0.3 um typical)
  • Step resolution
    - 5 nm (theoretical)
  • Unidirectional repeatability
    - < 0.2 um (< 0.1 um typical)
  • Maximum travel
    - 1 mm
  • Typical speed
    - 1000 um/sec
    XY axes
  • Absolute accuracy
    - < 10.0 um per 25 mm of travel
  • Unidirectional repeatability
    - < 0.4 um per axis (< 0.2 um typical)
  • Step resolution
    - 20 nm (theoretical)
  • Maximum travel
    - 25 mm X, Y (25 x 25 stage)
    - 25 mm (X) x 50mm (Y) (25 x 50 stage)
  • Typical speed
    - 2000 um/sec
    Illumination
  • 250 W Xe Fluorescence Illumination long-life bulb
    - More stable illumination for longer continuous experiments
    - Increased illumination for DAPI, GFP, Cy5
  • LED Transillumination
    - Better light concentration
    - Improved reliability
    - Faster on/off cycles
    - No mechanical shutters
    - Improved color balance
    Software
  • softWoRx 3.6.0
  • softWoRx Suite visualization and analysis
  • Data Management Server (DMS)
    - Image data management
    - Built on Open Microscopy Environment (OME) standards in collaboration with Glencoe Software, Inc.
  • Actions
    - Enables multi-channel PK experiments
    - Enables 3-D PK experiments
    - Optimize experiments for your applications
  • Multiplexed Wavelengths
    - Experiment design
    - Interleaved averaging
  • Enhanced Queue Management
    - System level queue
    - Deconvolution, volume rendering, movie creation
    - Chained events
  • Ratio Imaging
    - Bio-sensors
    - Calcium (Fura-2)
    - FRET Biosensors
    - On-the-fly visualization
    - Post-processing and analysis
    Workstation
  • Dual processor, dual core
  • 1TB RAID5
  • Multi-threaded deconvolution and rendering
  • More than 5X faster than previous version
  • CentOS EL4.0
  • USB drive support
  • DVD-R support
  • 24” LCD monitor
  • Backlit keyboard, laser mouse
    Options
  • Quantifiable Laser Module (QLM)
  • TIRF (includes QLM)
  • Live-cell Filter Set
  • WeatherStation environmental chamber
  • Cascade2 Camera
  • Standalone Workstation
  • Multiplexed Wavelengths Imaging
    - EGFP/mCherry Polychroic and Dual Band EM
    - CFP/YFP Polychroic and Dual Band EM
    Upgrades
  • Dual Processor, dual core computer 5TB RAID5
  • 30” monitor

personalDV

( Specifications subject to change )
    System Configuration
  • White LED transillumination
  • APLLC Xe illumination
  • Fast shutter
  • 10-position ND filter wheel
  • 10-position EX filter wheel
  • 6-position EM filter wheel
  • Optical fiber
  • Fiber Optic Module (FOM)
  • IX-71 microscope base
  • Custom DeltaVision Quad filter set
  • 60x objective/1.42NA
  • Stackable IC/MIC
  • Dual processor tower computer, 400GB
  • 25 mm stage
  • CoolSnap ES2 Camera (PCI)
  • Benchtop microscopy isolation platform
  • 19" monitor
  • Backlit keyboard, laser mouse
    Instrument Control
  • Instrument Control (IC) computer
  • Microscope Interface Chassis (MIC)
  • Lamp power supplies
  • NanoMotion® III Stage Control
  • Single enclosure design
  • Faster performance
    Stage Specifications
    Z axis
  • Absolute accuracy
    - < 0.6 um per 13 um Z scan
    - < 2.0 um per 100 um Z scan
  • Out-of-axis motion
    - < 0.6 um per 13 um Z scan (< 0.3 um typical)
  • Step resolution
    - 5 nm (theoretical)
  • Unidirectional repeatability
    - < 0.2 um (< 0.1 um typical)
  • Maximum travel
    - 1 mm
  • Typical speed
    - 1000 um/sec
    XY axes
  • Absolute accuracy
    - < 10.0 um per 25 mm of travel
  • Unidirectional repeatability
    - < 0.4 um per axis (< 0.2 um typical)
  • Step resolution
    - 20 nm (theoretical)
  • Maximum travel
    - 25 mm X, Y (25 x 25 stage)
    - 25 mm (X) x 50mm (Y) (25 x 50 stage)
  • Typical speed
    - 2000 um/sec
    Illumination
  • 250 W Xe Fluorescence Illumination Long-life bulb
    - 10X longer bulb life (>1000 hours)
    - More stable illumination for longer continuous experiments
    - Increased illumination for DAPI, GFP, Cy5
  • LED Transillumination
    - Better light concentration
    - Improved reliability
    - Faster on/off cycles
    - No mechanical shutters
    - Improved color balance
    Software
  • softWoRx 3.6.0
  • Actions
    - Optimize experiments for your applications
  • Ratio Imaging
    - Bio-sensors
    - Calcium (Fura-2)
    - FRET Biosensors
    - On-the-fly visualization
    - Post-processing and analysis
  • Enhanced Queue Management
    - System level queue
    - Deconvolution, Volume Rendering, Movie creation
    - Chained events
  • Optional Data Management Solution (DMS) support
    - Image data processing, management and storage
    - Built on Open Microscopy Environment (OME) standards in collaboration with Glencoe Software, Inc.
  • Optional Multiplexed Wavelengths Imaging support
    - Experiment design
    - Interleaved averaging
    Workstation
  • Dual processor
  • 400 GB storage
  • High capacity, high speed
  • Multi-threaded deconvolution and rendering
  • More than 5X faster than previous version
  • CentOS EL4.0
  • USB drive support
  • DVD-R support
  • 19” LCD monitor
  • Backlit keyboard, laser mouse
    Options
  • WeatherStation environmental chamber
  • Live-cell filter set
  • softWoRx Suite visualization and analysis software
  • Standalone Workstation
  • Data Management Solution (DMS)
  • Multiplexed Wavelengths Imaging
    - EGFP/mCherry Polychroic and Dual Band EM
    - CFP/YFP Polychroic and Dual Band EM
    Upgrades
  • 25 mm x 50 mm long travel stage
  • CoolSnap HQ2 Camera
  • DeltaVision Isolation Table
  • 24" monitor

Applied Precision, DeltaVision and softWoRx are registered trademarks of Applied Precision, LLC.
All other trademarks are the property of their respective owners.


© 2008 Applied Precision, Inc